The goal of the second query is to monitor the energy consumption of the manufacturing equipment. The energy consumption is recorded by the sensors mf01, mf02, and mf03. The first set of operators (operator 1 till 3) calculates the average values for each of the sensors (s1.avg-mf01 till s1.avg-mf03) as well as the relative variation (s1.rng-mf01 till s1.rng-mf03) in each of the sensors readings. Both average and variation values are calculated over the period of 1 second and are output every second.

The relative variation is used to trigger the recording of the raw values of the sensor readings -- see operator 4. Whenever the relative variation on any of the energy measuring sensors exceeds the threshold of 30%, the raw data from each of the sensors (mf01-mf03) needs to be recorded starting 20 seconds before the occurrence of the threshold violation and ending 70 seconds afterwards. If multiple violations occur with the 90 second interval, it needs to be extended so that it always captures 70 seconds of raw data after the occurrence of the last violation and 20 seconds before the occurrence of the first violation.

Finally, operators 5 till 7 record the power consumption of the manufacturing equipment within a period of one minute.